HPLC Column, RP C12, 3um, 2.1mm ID x 50mm Length, 100A. Cogent Brand. 1 EA.
Additional Information:
Cogent RP C12™ is a unique reversed-phase HPLC stationary phase designed to provide balanced hydrophobic retention, rapid equilibration, and excellent reproducibility. Manufactured using a rigid adamantane-shaped carbon silane bonded to ultra-high purity silica and fully double end capped, this stationary phase offers selectivity that falls between traditional C8 and C18 phases. The distinctive ligand structure provides excellent performance for complex mixtures and applications requiring robust retention behavior across a wide range of mobile-phase conditions.
68312-05P-2 is an HPLC column packed with 3 µm RP C12™ particles featuring a 100 Å pore size in a 2.1 mm ID x 50 mm format. This short, narrow-bore configuration is optimized for rapid separations, reduced solvent consumption, and excellent compatibility with LC-MS instrumentation. The 3 µm particles provide greater efficiency and sharper peaks than comparable 5 µm columns, while the short 50 mm length minimizes run times for high-throughput workflows. Typical operating flow rates are approximately 0.2–0.3 mL/min. Because of the low flow rates required by 2.1 mm ID columns, standard HPLC systems must be capable of precise and reproducible low-flow operation.
Compatible with virtually all reversed-phase mobile phases, including 100% aqueous conditions, this column maintains consistent retention without the phase collapse often associated with some traditional reversed-phase columns. Retention is typically greater than C8 phases and lower than C18 phases for the same hydrophobic compounds. This format is especially popular for LC-MS applications, high-throughput screening (HTS), and rapid analytical methods.
Key Benefits
RP C12™ stationary phase
Fully double end capped
Adamantane-shaped bonded ligand
Ultra-high purity silica support
Compatible with 100% aqueous mobile phases
Rapid equilibration between runs
3 µm particle size
Greater efficiency than 5 µm columns
Excellent for LC-MS and HTS methods
Retention characteristics between C8 and C18 phases
Typical Applications
High-throughput screening (HTS)
LC-MS methods
Reversed-phase HPLC
Complex mixture separations
Pharmaceutical analysis
Method development
Quality control testing
Hydrophobic compound analysis
Gradient separations
Research and development
Specifications
Product Type: HPLC Column
Stationary Phase: RP C12™
Chromatography Mode: Reversed Phase
Bonded Phase: Adamantane Carbon Silane
Endcapping: Fully Double End Capped
Particle Size: 3 µm
Pore Size: 100 Å
Column Dimensions: 2.1 mm ID x 50 mm
Length: 50 mm
Typical Flow Rate: 0.2–0.3 mL/min
Brand: Cogent
Important Notes
Compatible with 100% aqueous mobile phases
Maintains consistent retention from run to run
Rapid equilibration supports high-throughput workflows
The 2.1 mm ID format is commonly used for LC-MS applications
Standard HPLC systems must be capable of precise and reproducible operation at approximately 0.2–0.3 mL/min
Detector flow cells should be optimized for low-volume, narrow-bore chromatography
3 µm particles provide higher efficiency and sharper peaks than comparable 5 µm columns
Generates higher backpressure than larger particle columns
The 50 mm length is ideal for rapid analyses and increased sample throughput
Retention is generally greater than C8 phases and less than C18 phases